Abstract

An analytical method for the determination of norethisterone acetate (NETA) in human plasma by capillary gas chromatography-mass-selective detection (GC-MS), with testosterone acetate as internal standard, was developed and validated. After addition of the internal standard, the compounds were extracted from plasma at basic pH into diethyl ether-dichloromethane (3:2 v/v), which was then evaporated to dryness. The compounds were converted into their pentafluoropropionyl derivatives which were determined by gas chromatography using a mass selective detector at m/z 486 for NETA and m/z 476 for the internal standard. Intra-day and inter-day accuracy and precision were found suitable over the range of concentrations between 0.10 to 10 ng/ml. The method was applied to clinical samples.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.