Abstract
A series piezoelectric quartz crystal (SPQC) sensor was developed for quantitative determination of Lactobacillus spp. populations in milk. When the electrodes were immersed in a reaction cell with bacterial inoculum, the change of frequency was caused by the impedance change of the microbial metabolism. A significant frequency decrease was found due to the coagulation of milk when the Lactobacillus spp. was cultivated in the media. The SPQC sensor system established in this study demonstrated the specificity and selectivity for detection of Lactobacillus spp. in milk sample. The calibration curve of detection time against density of Lactobacillus spp. shows a linear correlation coefficient (R2 = 0.8453) over the range of 102–2.4 × 105 CFU ml−1. The detection time was influenced by the addition of peptone and glucose. The sensor exhibited rapid (within 4 h) and enabled real time monitoring of Lactobacillus spp. growth. This system is potentially applicable to detect Lactobacillus spp. concentration at local farm when a suitable temperature control device is adapted.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.