Abstract
A sensitive, selective and reliable procedure was developed and validated to determine organochlorinated compounds, which have endocrine-disrupting effects, in human serum. Target compounds were selected between polychlorinated biphenyls and organochlorinated pesticides. Sample workup consisted of (1) extraction of serum with organic solvents, (2) clean-up of the organic extract using acid treatment with H(2)SO(4), (3) elution of the cleaned-up extract through a liquid column chromatographic system and (4) analysis of the fraction eluted by gas chromatography with electron capture detection (ECD) and tandem mass spectrometry (MS/MS) detection. Performance characteristics, such as linearity, sensitivity, precision, accuracy and recovery, of both chromatographic methods were studied. The proposed analytical methodology was applied to determine the target compounds in serum samples from women living in agricultural areas of Almería (Spain). The results show the advantage of MS/MS over ECD in the analysis of real human serum samples where matrix interferences can be confused with target pesticides.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.