Lamivudine (3TC) and zidovudine (AZT) are systemic antiviral substances extensively used in human immunodeficiency virus (HIV) infected patients. Nowadays, 3TC, AZT, and several other pharmacologically potent pharmaceuticals are manufactured in the same production area. To assure quality of drug products and patient safety, properly validated cleaning methodology is necessary. A carefully designed cleaning validation and its evaluation can ensure that residues of 3TC and AZT will not carry over and cross contaminate the subsequent product. The aim of this study was to validate a simple analytical method for verification of residual 3TC and AZT in equipment used in the production area and to confirm the efficiency of the cleaning procedure. The liquid chromatography method was validated using a Nova-Pak C18 column (3.9 x 150 mm, 4 microm particle size) and methanol-water (20 + 80, v/v) as the mobile phase at a flow rate of 1.0 mL/min. Ultraviolet detection was made at 266 nm. The calibration curve was linear over a concentration range of 2.0-22.0 microg/mL with a correlation coefficient of 0.9998. The detection and quantitation limits were 0.36 and 1.21 microg/mL, respectively. The intra-day and interday precision expressed as relative standard deviation were below 2.0%. The mean recovery of the method was 99.19%. The mean extraction recovery from manufacturing equipment was 83.5%.