Gait of single-radius (SR, n=16) and multi-radius (MR, n=16) posterior stabilized total knee arthroplasties was compared, along with controls (n=16), pre-op and 1year post-op. Computer navigation and standard order sets controlled confounding variables. Post-operatively, SR knees did not differ from controls while MR knees continued to differ in important knee kinetic and kinematic properties. MR knees remained more extended (P=0.019) and had decreased power absorption (P=0.0001) during weight acceptance compared to the SR knees. Both surgical groups had similar KSS for Knee Scores (P=0.22) and Function Scores (P=0.58). The significant biomechanical differences are likely influenced by patella–femoral moment arm geometry and changing ligament laxity throughout the active range of motion.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.