A calibrated, nonintrusive optical technique, laser-induced iodine fluorescence (LIIF) was used to quantify the steady, compressible flowfield of a nonreacting, supersonic combustor. The combustor was configured with single and staged, transverse-air injection into a supersonic-air freestream behind a rearward-facing step. Pressure, temperature, two-velocity components, and injectant mole fraction were measured with high spatial resolution in the three-dimensional flowfields. These experimental results provide a benchmark set of data for validation of computational fluid dynamic (CFD) codes being developed to model supersonic combustor flowfields.