Abstract

Previous presence/absence studies have indicated a correlation between the presence of the pathogenic amoeba Naegleria fowleri and the presence of bacteria, such as the fecal indicator Escherichia coli, in environmental surface waters. The objective of this study was to use quantitative real-time polymerase chain reaction (qPCR) methodologies to measure N. fowleri and E. coli concentrations within a Texas reservoir in late summer, and to determine if concentrations of N. fowleri and E. coli were statistically correlated. N. fowleri was detected in water samples from 67% of the reservoir sites tested, with concentrations ranging up to an estimated 26 CE (cell equivalents)/100 mL. E. coli was detected in water samples from 60% of the reservoir sites tested, with concentrations ranging up to 427 CE/100 mL. In this study, E. coli concentrations were not indicative of N. fowleri concentrations.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.