Abstract

Diagnostic assessment of industrial floor using the methodology of quantitative evaluation of concrete microstructure is presented. Symptoms of damage included surface dusting and delamination of the top layer. A petrographic analysis of the concrete composition in core specimens was carried out. Excessive air content, accumulation of air voids and the occurrence of oriented cracks, local variability of the phase composition of cement hydration products, including the occurrence of carbonated areas were observed and associated with the premature surface damage

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.