Abstract

BackgroundFacial symmetry is becoming increasingly important in today's orthodontic treatment. But the asymmetrical boundary is not clearly demarcated. Stereophotogrammetry has a clear advantage in measuring facial asymmetry. The aim of this study was to quantify the facial asymmetry by three-dimensional (3D) technology as well as to study whether the evaluation by non-experts about facial asymmetry was consistent with the analysis by 3D technology.MethodsThe facial symmetry of 330 patients was evaluated by 10 non-experts. 3D facial images were taken using 3dMD stereophotogrammetry equipment. The original face and its mirror shell were divided into 7 regions and the surface matching was measured in the whole face and all regional areas. The degree of symmetry was calculated by the software 3-matic STL 9.0. The difference between the two groups was analyzed by Independent-Samples T Test and the diagnostic efficiency of symmetry degree was analyzed by ROC curve analysis. The consistency between the symmetric degree and the result of evaluation was analyzed by Pearson correlation analysis.ResultsThe ROC analysis revealed significant diagnostic values in the determination of the facial asymmetry of lip, chin, cheek and lateral mandible areas. The cut-off values of symmetry degree were between 60 and 80%. The evaluation was middle correlation with the symmetric degree of the whole face.ConclusionsThe chin and lateral mandible contribute most significantly to the facial symmetry. The objective measurement of facial symmetry, 3D technology, is reliable.

Full Text
Published version (Free)

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call