Abstract

The Shanghai Electric – Siemens ultra-supercritical 660 MW steam turbine has a large proportion in the newly produced 600 MW units in China in recent years because of its superior performance index. It has become an important development direction of 600 MW level ultra-supercritical power generation technology. Taking a N660-25/600/600 steam turbine as an example, the quantitative sensitivity analysis of energy consumption of the high-pressure cylinder, intermediate-pressure cylinder and low-pressure cylinder were carried out based on the calculation method of rated power and variable condition, the influence of each cylinder efficiency change on the heat consumption rate of steam turbine is obtained. It turns out that the efficiency of high-pressure cylinder is less sensitive to energy consumption, the efficiency of intermediate-pressure cylinder is second, and the efficiency of low-pressure cylinder is more sensitive to energy consumption. The conclusion can provide technical reference for energy conservation diagnosis and energy conservation management and evaluation on this type of steam turbine.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.