Abstract

A novel precolumn derivatization-gas chromatography tandem mass spectrometry (GC-MS/MS) method was developed to detect and confirm the presence of decoquinate residues in eggs (whole egg, albumen and yolk). Liquid-liquid extraction (LLE) and solid phase extraction (SPE) were used to extract and purify samples. The derivatization reagents were pyridine and acetic anhydride, and the derivatives were subjected to GC-MS/MS detection. After the experimental conditions were optimized, satisfactory sensitivity was obtained. The limits of detection (LODs) and limits of quantification (LOQs) for the decoquinate in eggs (whole egg, albumen and yolk) were 1.4-2.4 μg/kg and 2.1-4.9 μg/kg, respectively. At four spiked concentration levels, the average recoveries were 74.3-89.8%, the intraday RSDs ranged from 1.22% to 4.78%, and the inter-day RSDs ranged from 1.61% to 7.54%. The feasibility and practicality of the method were confirmed by testing egg samples from a local supermarket.

Full Text
Published version (Free)

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call