Abstract
The chain-length distribution of debranched amylopectin was analyzed by using high performance anion-exchange chromatography with an amyloglucosidase (AMG) reactor and a pulsed amperometric detector (HPAEC-ENZ-PAD). The effects of reactor length, reactor temperature, and additional a-amylase reactor were studied. Results showed that a 2 mm i.d. x 23 mm AMG reactor at 25%°C was sufficient to convert HPAEC-separated amylodextrins to glucose; the PAD response for the hydrolyzed amylodextrins of different chain-length was consistent, and quantitative results were achieved. With this enzymatic treatment, amylodextrin with DP up to 77 was detected for a debranched tapioca amylopectin sample. The chain-length distribution profile of debranched tapioca amylopectin showed three fractions with peak DPs 48± 1 (Fl), 19 (F2a), and 12 (F2b).
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
More From: Journal of Liquid Chromatography & Related Technologies
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.