Abstract

During one-lung ventilation, ventilation-perfusion mismatch decreases the arterial concentration of inhaled anaesthetics due to the arterial-to-venous concentration difference. This study tested the hypothesis that in humans, the 'presumed effect-site concentration' (taken as the mid-point between the arterial and superior jugular venous concentrations) of inhaled anaesthetic falls during one-lung (vs two-lung) ventilation. Four patients scheduled for elective prostatectomy (two-lung ventilation) and four patients for elective thoracotomy (one-lung ventilation) were randomly selected and assigned to receive sevoflurane (vaporiser-dial setting, 1.5%). Sevoflurane concentrations were measured periodically from radial artery and superior jugular vein (via a catheter advanced cephalad from the jugular vein). During one-lung ventilation, the end-expiratory sevoflurane concentration was stable at ∼1.3% but the mean (SD) presumed effect-site concentration declined initially from 58 (6.7) to 43 (4.7) μg.ml(-1) (p=0.011) before slowly recovering. A period of insufficient depth of anaesthesia is thus a risk during one-lung ventilation.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.