Abstract
Wear particles produced by vibratory cavitation erosion tests on 1017 carbon steels in water and oil-in-water (o∕w) emulsions were analyzed. Scanning electron microscope (SEM) images of wear particles were acquired, forming a database for further analysis. The particle morphology features were first clarified. Next, the size parameters (size, area, and perimeter) and shape factors (elongation and roundness) were determined for each test liquid, using image analysis software. The size parameters of the removed particles were higher in water than in o∕w emulsions. While the shape factors could not significantly discriminate between the particles produced in water and o∕w emulsions. The size distribution was in a wide range for water than that for o∕w emulsions. The cavitation erosion mechanism is fatigue failure for water and o∕w emulsions.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.