Abstract
Calorific value is an essential fuel parameter during the process of energy utilization. Forty-four coal samples with different calorific values were quantitatively analyzed by laser-induced breakdown spectroscopy (LIBS) in this paper. The influences of different spectral preprocessing methods such as smoothing, standard normal variate transformation (SNV), multiplicative scatter correction (MSC), mean centering (MC), and derivation by convolution (Savitzky–Golay) on the quantitative model have been analyzed and compared. The results showed that the quantitative model obtained the best comprehensive performance with the application of the 11 points smoothing combined with the second-order derivation. The correlation coefficient of calibration set, correlation coefficient of validation set, RMSECV, and RMSEP were 0.9909, 0.9972, 0.467, and 0.276 MJ/kg, respectively, which were optimized compared with the traditional partial least-squares (PLS) model by 15.9%, 37.7%, 75.1%, and 88.3%, respectively. It indic...
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.