Abstract

Multiple techniques have been suggested to achieve control balance in single-phase three-level neutral-point clamped (3L-NPC) converters. Nevertheless, there is a deficiency of quantitative calculations related to the extent of balancing. Operating beyond the balancing range may result in a sequence of safety incidents. This paper presents a conceptualization of the 3L-NPC converter as two cascaded H-bridges. By employing power conservation principles, the balancing range for the NPC converter is derived, and two novel methods are investigated to broaden the balance range in accordance with the calculated balance range. A comparison is made among the balancing ranges under different balancing control methods. This study establishes a theoretical foundation to ensure the secure and stable operation of the NPC converter.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.