Abstract

A simple ion-pairing reverse-phase HPLC method, with UV diode array detection, was developed and validated for quantitation of the urinary niacin metabolites 1-methylnicotinamide and l-methyl-2-pyridone-5-carboxamide in a single run. Urine samples were purified using a polymer-based mixed mode anion exchange reverse-phase cartridge. Analysis was performed on a reverse-phase C18 column, using a methanol gradient elution system, containing phosphate buffer pH 7.0, 1-heptanesulphonic acid as the ion-pairing agent and trimethylamine as a modifier. The assay was applied to the measurement of the niacin status of two subjects using spot urine samples. The samples were collected over 4 consecutive days and at four time points during 1 day. Status, expressed as the concentration ratios (2-PYR or 1-MN)/creatinine and 2-PYR/l-MN, varied within and between days and was least for fasting samples. This work illustrates the potential of spot urine sampling for niacin status assessment, but highlights the need for further validation prior to its use in field nutritional surveys.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.