A reversed-phase high performance liquid chromatographic (LC), tandem mass spectrometry (MS/MS) assay for the determination of tenofovir (TFV) and emtricitabine (FTC) in dried blood spots (DBS) from human whole blood was developed and validated. Whole blood samples were spotted, dried, and a 3mm punch was extracted with methanol for analysis by LC–MS/MS utilizing stable isotope labeled internal standards. The assay was validated over the range of 2.5–1000ng/mL for TFV and 2.5–5000ng/mL for FTC. The method was accurate (within ±15% of control) and precise (coefficient of variation ≤15%) for hematocrit concentrations ranging from 25% to 76%; using edge punches vs. center punches; and spot volumes of 10–50μL. Analytes were stable for five freeze/thaw cycles and up to 6 days at room temperature, whereas long-term storage required −20°C or −80°C. Comparison of TFV and FTC in DBS vs. plasma yielded r2≥0.96, indicating that DBS can be used as a plasma alternative for pharmacokinetic analyses in vivo.
Accepted Version (Free)
Published Version
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.