Abstract
This paper describes an analytical procedure for the quantitative determination of the pharmaceutical vehicle Cremophor EL in human plasma samples. The procedure is based on rapid binding of Coomassie brilliant blue G-250 to Cremophor EL following plasma protein precipitation with acetonitrile and analyte extraction withn-butylchloride. The binding of the dye to Cremophor EL causes a shift in the absorption maximum from 465 to 624 nm, which is monitored using an automated microplate-absorbance reader. The assay permits estimation of Cremophor EL concentrations in the range 0.05–1.00% (v/v) in 50 μL of human plasma, with percentage deviation and precision of ≤12 and ≤15%, respectively. The assay was subsequently used to measure Cremophor EL concentrations in plasma samples in support of a project to develop a pharmacokinetic model for this compound in patients receiving paclitaxel.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.