Abstract

In the USA, the potency of commercially prepared equine tetanus antitoxin is determined by the method outlined in the Code of Federal Regulations, Title 9, Part 113.451. In the current test, commercial equine tetanus antitoxin is tested by a toxin neutralization test in guinea pigs. The in vivo test measures antitoxin content through effectiveness of protection of guinea pigs injected with diluted mixtures of antitoxin and a standard toxin. A competitive enzyme-linked immunosorbent assay, designed as an in vitro alternative to the in vivo test, measures antitoxin content based on a competitive reaction between standard or unknown serum and murine monoclonal antibody specific for tetanus toxin. The monoclonal antibody used in the assay delayed death in mouse passive protection studies and reacted with the C fragment of tetanus toxin. No cross-reaction was observed when the antibody was tested with the toxins of Clostridium chauvoei, C. novyi, C. perfringens, or C. sordellii. The in vitro test will measure the antitoxin content of serum samples containing 100–1500 units of antitoxin. Tetanus antitoxin titers obtained by the competitive enzyme-linked immunosorbent assay compared favorably with the toxin neutralization test conducted in guinea pigs. The in vitro assay serves as a feasible alternative to the in vivo test because it can be completed in less time, is reproducible, and eliminates the use of test animals.

Full Text
Published version (Free)

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call