Abstract

A rapid and sensitive method for the analysis of 17alpha-ethinylestradiol (EE2) in environmental aqueous samples has been developed. Aquatic samples were extracted using liquid-liquid extraction, and organic phase extracts were concentrated and derivatized with dansyl chloride. Analysis was performed using high-performance liquid chromatography with positive electrospray ionization and tandem mass spectrometry (HPLC/ESI-MS/MS). Deuterated 17alpha-ethinylestradiol was used as internal standard and was added to samples before extraction. A limit of quantitation of 1 ng/L was obtained using a 25 mL aqueous sample. The average recovery of EE2 spiked into a 25 mL tapwater sample was 100%. This highly sensitive quantitation method is useful for measuring low levels of EE2 in aqueous environmental samples.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.