Abstract

In metabolomic research, it is important to reduce systematic error in experimental conditions. To ensure that metabolomic data from different studies are comparable, it is necessary to remove unwanted systematic factors by data normalization. Several normalization methods are used for metabolomic data, but the best method has not yet been identified. In this study, to reduce variation from non-biological systematic errors, we applied 1-norm, 2-norm, and quantile normalization methods to liquid chromatography-mass spectrometry (LC-MS)-based metabolomic data from human urine samples after oral administration of cyclosporine (high- and low-dose) in healthy volunteers and compared the effectiveness of the three methods. The principal component analysis (PCA) score plot showed more obvious groupings according to the cyclosporine dose after quantile normalization than after the other two methods and prior to normalization. Quantile normalization is a simple and effective method to reduce non-biological systematic variation from human LC-MS-based metabolomic data, revealing the biological variance.

Full Text
Published version (Free)

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call