Abstract

This paper attempts to quantify the effects of array layout on the performance of offshore wind farms. Array layout is characterized by the spacing between wind turbines (along and across the prevailing wind direction) and by their alignment (aligned or staggered). A large‐eddy simulation code is utilized to create a turbulent boundary layer and is coupled with an actuator line model to simulate the effects of the rotating wind turbine blades. A control case (simulating the Lillgrund farm) and sensitivity runs are performed with various combinations of increased spacing, with and without staggering. Staggering every second row was found to be the simplest method to improve the capacity factor from 0.3 to 0.34 and array losses from 36% to 27%. The highest capacity factor (0.4) and the lowest array losses (14%) were obtained with a staggered layout with spacing across the prevailing wind direction that was twice the original. Smart layout choices can improve the array performance by 13%–33%.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.