Abstract

AimsThe aim of this study was to report the metrological qualities of techniques currently used to quantify skeletal muscle volume and 3D shape in healthy and pathological muscles.MethodsA systematic review was conducted (Prospero CRD42018082708). PubMed, Web of Science, Cochrane and Scopus databases were searched using relevant keywords and inclusion/exclusion criteria. The quality of the articles was evaluated using a customized scale.ResultsThirty articles were included, 6 of which included pathological muscles. Most evaluated lower limb muscles. Partially or completely automatic and manual techniques were assessed in 10 and 24 articles, respectively. Manual slice-by-slice segmentation reliability was good-to-excellent (n = 8 articles) and validity against dissection was moderate to good(n = 1). Manual slice-by-slice segmentation was used as a gold-standard method in the other articles. Reduction of the number of manually segmented slices (n = 6) provided good to excellent validity if a sufficient number of appropriate slices was chosen. Segmentation on one slice (n = 11) increased volume errors. The Deformation of a Parametric Specific Object (DPSO) method (n = 5) decreased the number of manually-segmented slices required for any chosen level of error. Other automatic techniques combined with different statistical shape or atlas/images-based methods (n = 4) had good validity. Some particularities were highlighted for specific muscles. Except for manual slice by slice segmentation, reliability has rarely been reported.ConclusionsThe results of this systematic review help the choice of appropriate segmentation techniques, according to the purpose of the measurement. In healthy populations, techniques that greatly simplified the process of manual segmentation yielded greater errors in volume and shape estimations. Reduction of the number of manually segmented slices was possible with appropriately chosen segmented slices or with DPSO. Other automatic techniques showed promise, but data were insufficient for their validation. More data on the metrological quality of techniques used in the cases of muscle pathology are required.

Highlights

  • The volume and shape of a muscle are strongly related to its function [1,2,3,4]

  • The Deformation of a Parametric Specific Object (DPSO) method (n = 5) decreased the number of manually-segmented slices required for any chosen level of error

  • The results of this systematic review help the choice of appropriate segmentation techniques, according to the purpose of the measurement

Read more

Summary

Introduction

The volume and shape of a muscle are strongly related to its function [1,2,3,4]. Physiological cross-sectional area is the major determinant of joint torque [1]. Muscle volume, which is closely related to physiological cross sectional area, was shown to be strongly connected with joint torque in both healthy and pathological populations [2,3,4,5]. Changes in muscle volumes and shapes may be normal, such as hypertrophy after a strengthening program, or atrophy associated with ageing [6,7]. Changes can be pathological due to neuromuscular disease or injury [5,8,9]

Methods
Results
Discussion
Conclusion
Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.