Abstract
Idiopathic intracranial hypertension (IIH) is characterized by elevated intracranial pressure without a clear cause. To investigate dynamic imaging findings in IIH and their relation to mechanisms underlying intracranial pressure normalization. Prospective. Eighteen IIH patients and 30 healthy controls. T1 -weighted, venography, fluid attenuation inversion recovery, and apparent diffusion coefficients were acquired on 1.5T scanner. The dural sinus was measured before and after lumbar puncture (LP). The degree of sinus occlusion was evaluated, based on 95% confidence intervals of controls. We studied a number of neuroimaging biomarkers associated with IIH (sinus occlusion; optic nerve; distribution of cerebrospinal fluid into the subarachnoid space, sulci and lateral ventricles (LVs); Meckel's caves; arachnoid granulation; pituitary and choroid plexus), before and after LP, using a set of specially developed quantification techniques. Relationships among various biomarkers were investigated (Pearson correlation coefficient) and linked to long-term disease outcomes (logistic regression). The t-test and the Wilcoxon rank test were used to compare between controls and before and after LP data. As a result of LP, the following were found to be in good accordance with the opening pressure: relative compression of cerebrospinal fluid (R = -0.857, P < 0.001) and brain volumes (R = -0.576, P = 0.012), LV expansion (R = 0.772, P < 0.001) and venous volume (R = 0.696, P = 0.001), enlargement of the pituitary (R = 0.640, P = 0.023), and shrinkage of subarachnoid space (R = -0.887, P < 0.001). The only parameter that had an impact on long-term prognosis was cross-sectional size of supplemental drainage veins after LP (sensitivity of 92%, specificity of 20%, and area under the curve of 0.845, P < 0.001). We present an approach for quantitative characterization of the intracranial venous system and its implementation as a diagnostic assistance tool. We conclude that formation of supplementary drainage veins might serve as a long-lasting compensatory mechanism. 2 Technical Efficacy: Stage 3 J. Magn. Reson. Imaging 2018;47:913-927.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.