Abstract

The reliability of a handheld myotonometer when used in a clinical setting to assess paraspinal muscle mechanical properties is unclear. This study aimed to investigate the between-session intra-rater reliability of a handheld myotonometer in young adults with low back pain (LBP) in a clinical environment. One assessor recorded lumbar paraspinal muscle tone and stiffness in an outpatient department on two occasions. The intraclass correlation coefficient (ICC), standard error of measurement (SEM), smallest real difference (SRD) and Bland-Altman analysis were conducted to assess reliability. The results indicated acceptable between-days intra-rater reliability (ICC > 0.75) for all measurements. The SEM of the muscle tone and stiffness measurements ranged between 0.20–0.66 Hz and 7.91–16.51 N/m, respectively. The SRD was 0.44–1.83 Hz for muscle tone and 21.93–52.87 N/m for muscle stiffness. SEM and SRD at L1-L2 were higher than those at other levels. The magnitude of agreement appeared to decrease as muscle tone and stiffness increased. The myotonometer demonstrated acceptable reliability when used in a clinical setting in young adults with chronic LBP. Measurements of the upper lumbar levels were not as reliable as those of the lower lumbar levels. The crural attachment of the diaphragm at L1 and L2 may affect paraspinal muscle tone and stiffness during respiratory cycles.

Highlights

  • Chronic low back pain (LBP) is among the leading causes contributing to years of living with a disability worldwide[1]

  • We found no published data documenting the reliability of a handheld myotonometer in measuring paraspinal muscle tone and stiffness in young adults with chronic LBP in an outpatient setting

  • Thirty participants with chronic LBP were recruited in the study

Read more

Summary

Introduction

Chronic low back pain (LBP) is among the leading causes contributing to years of living with a disability worldwide[1]. Recent studies have demonstrated the feasibility of using the handheld myotonometer to differentiate lumbar extensor fascia stiffness between young patients diagnosed with ankylosing spondylitis and healthy individuals[5,31]. Despite these positive results, several authors have raised doubts about the reliability of myotonometers when used in pathological groups[27] or when used in a clinical environment[26]. We found no published data documenting the reliability of a handheld myotonometer in measuring paraspinal muscle tone and stiffness in young adults with chronic LBP in an outpatient setting. The aim of this study was to assess the between-session intra-rater reliability of a handheld myotonometer in young adults with chronic LBP in a musculoskeletal outpatient setting

Objectives
Methods
Results
Conclusion
Full Text
Published version (Free)

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call