Abstract
Conventional echocardiographic diastolic function (DF) assessment approximates transmitral flow velocity contours (Doppler E-waves) as triangles, with peak (Epeak), acceleration time (AT), and deceleration time (DT) as indexes. These metrics have limited value because they are unable to characterize the underlying physiology. The parametrized diastolic filling (PDF) formalism provides a physiologic, kinematic mechanism based characterization of DF by extracting chamber stiffness (k), relaxation (c), and load (x o ) from E-wave contours. We derive the mathematical relationship between the PDF parameters and Epeak, AT, DT and thereby introduce the geometric method (GM) that computes the PDF parameters using Epeak, AT, and DT as input. Numerical experiments validated GM by analysis of 208 E-waves from 31 datasets spanning the full range of clinical diastolic function. GM yielded indistinguishableaverage parameter values per subject vs. the gold-standard PDF method(k: R2=0.94, c:R2=0.95, x o :R2=0.95, p<0.01 all parameters). Additionally, inter-rater reliability for GM-determined parameters was excellent (k:ICC=0.956c:ICC=0.944, x o :ICC=0.993). Results indicate that E-wave symmetry (AT/DT) may comprise a new index of DF. By employing indexes (Epeak, AT, DT) that are already in standard clinical use the GM capitalizes on the power of the PDF method to quantify DF in terms of physiologic chamber properties.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.