Abstract

Closed-form expressions of radiated emissions from power distribution networks (PDNs) in packages are derived based on the equivalent lumped-circuit model. The expressions are validated with results from full-wave numerical computations and far-field measurements. The effects of the small planar PDN structures on radiated emissions are quantitatively investigated based on the sensitivity analysis. Using the closed-form expressions, a systematic procedure for developing quantified PDN design guidelines to suppress the radiated emissions is formulated, which is then demonstrated with a test prototype PDN. The method allows the electromagnetic compatibility aware PDN design in the initial design stage.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.