Abstract

Background Volatile acetone is a potential biomarker that is elevated in various disease states. Measuring acetone in exhaled breath is complicated by the fact that the molecule might be present as both monomers and dimers, but in inconsistent ratios. Ignoring the molecular form leads to incorrect measured concentrations. Our first goal was to evaluate the monomer-dimer ratio in ambient air, critically ill patients, and rats. Our second goal was to confirm the accuracy of the combined (monomer and dimer) analysis by comparison to a reference calibration system. Methods Volatile acetone intensities from exhaled air of ten intubated, critically ill patients, and ten ventilated Sprague-Dawley rats were recorded using ion-mobility spectrometry. Acetone concentrations in ambient air in an intensive care unit and in a laboratory were determined over 24 hours. The calibration reference was pure acetone vaporized by a gas generator at concentrations from 5 to 45 ppbv (parts per billion by volume). Results Acetone concentrations in ambient laboratory air were only slightly greater (5.6 ppbv; 95% CI 5.1–6.2) than in ambient air in an intensive care unit (5.1 ppbv; 95% CI 4.4–5.5; p < 0.001). Exhaled acetone concentrations were only slightly greater in rats (10.3 ppbv; 95% CI 9.7–10.9) than in critically ill patients (9.5 ppbv; 95% CI 7.9–11.1; p < 0.001). Vaporization yielded acetone monomers (1.3–5.3 mV) and dimers (1.4–621 mV). Acetone concentrations (ppbv) and corresponding acetone monomer and dimer intensities (mV) revealed a high coefficient of determination (R2 = 0.96). The calibration curve for acetone concentration (ppbv) and total acetone (monomers added to twice the dimers; mV) was described by the exponential growth 3-parameter model, with an R2 = 0.98. Conclusion The ratio of acetone monomer and dimer is inconsistent and varies in ambient air from place-to-place and across individual humans and rats. Monomers and dimers must therefore be considered when quantifying acetone. Combining the two accurately assesses total volatile acetone.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.