Abstract

Abstract A method has been developed for quantification of trace rare earth (Ce, Dy, Er, Eu, Gd, Ho, La, Nd, Pr, Sm, Tb and Yb) impurities in alumina and aluminum by inductively coupled plasma mass spectrometry (ICP-MS) after matrix separation. The matrix separation was achieved by selective precipitation of trace elements. Due to its refractory nature a microwave digestion method was developed and optimized for the quantitative dissolution of Al2O3. The analytical methodology was validated by recovery studies with standard addition as well as with an independent γ-spectrometry technique using 152,154Eu tracers. The observed recovery in the synthetic samples was in the range of 93–100% with precision within 6.1–11.6 (%RSD), while the same in the case of radio tracer technique were found to be >98% and <2% (RSD), respectively. The method detection limit was found within 0.5–8.3 μg kg−1, respectively. The procedure is simple, organic waste free and suitable for routine analysis.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.