This study describes the use of electrochemical sensors to detect and quantify several statins (rosuvastatin and simvastatin) in pharmaceutical products. Two types of commercially screen-printed sensors were used and compared: one based on carbon (SPCE) and the other modified with gold nanoparticles and multi-walled carbon nanotubes (SPE/GNP-MWCNT). Cyclic voltammetry was employed for determination. The AuNP-MWCNTs/SPCE sensor outperformed the SPCE sensor, displaying excellent electrochemical properties. It demonstrated high sensitivity with low limits of detection (LOD) and quantification (LOQ) values: 0.15 µM and 5.03 µM, respectively, for rosuvastatin and 0.30 µM and 1.01 µM, respectively, for simvastatin. The sensor had a wide linear range of 20–275 µM for rosuvastatin and 50–350 µM for simvastatin. Using the AuNP-MWCNTs/SPCE sensor, rosuvastatin and simvastatin were successfully quantified in pharmaceutical products. The results were validated towards producer-reported values (standardized drugs) and a conventional analysis method (FTIR). The sensor exhibited excellent stability, reproducibility, and analytical recovery ranging from 99.3% to 106.6% with a low relative standard deviation (RSD) of less than 1%. In conclusion, the AuNP-MWCNTs/SPCE sensor proved to be a reliable and sensitive tool for detecting and quantifying statins in pharmaceutical products. Its superior electrochemical properties, low LOD and LOQ values, wide linear range, and high analytical recovery make it a promising choice for pharmaceutical quality control.