Abstract

Soft-tissue vibrations can be used to quantify selected properties of human tissue and their response to impact. Vibrations are typically quantified using high-speed motion capture or accelerometry. The aim of this study was to compare the amplitude and frequency of soft-tissue vibrations during running when quantified by highspeed motion capture and accelerometry simultaneously. This study showed: (a) The estimated measurement errors for amplitude and frequency were of the same order of magnitude for both techniques. (b) There were no significant differences in the mean peak frequencies and peak amplitudes measured by the two methods. (c) The video method showed an inability to capture high frequency information. This study has shown that a tradeoff has to be made between the accuracy in amplitude and frequency when these methods are employed to quantify soft tissue vibrations in running.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.