Abstract
Qualitative and semiquantitative contrast-enhanced (CE) dynamic perfusion MRI techniques are established as noninvasive diagnostic means of assessing coronary artery disease. However, to date quantification of myocardial blood flow (MBF) has not reached the same acceptance as MBF quantification with nuclear techniques. To validate quantification of MBF at rest using the extracellular contrast agent (CA) Gd-DTPA, we performed an animal study in a pig model of acute myocardial ischemia. We quantified MBF from MRI data with a mathematical model (MMID4) of the underlying vasculature. These MBF results were subsequently compared with the results from fluorescent microspheres. The study showed a correlation of r = 0.66 between MBF estimates obtained with MRI and those obtained with fluorescent microspheres. The correlation for ischemic and nonischemic myocardium was r = 0.86 and r = 0.47, respectively. In conclusion, quantification of resting MBF using MMID4 is a valid method under conditions of acute myocardial ischemia.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.