Abstract
Dual-energy computed tomography (DECT) is a promising technique for the assessment of the lung perfused blood volume (LPBV) in the lung parenchyma. This study was performed to compare the LPBV by DECT of patients with pulmonary hypertension (PH) and controls and to evaluate the association between the LPBV and the perfusion ratio derived by lung perfusion scintigraphy. This study involved 45 patients who underwent DECT (25 patients with PH and 20 controls). We measured the total LPBV and distribution of the LPBV in each lung. The total LPBV was significantly lower in the PH group than the control group (38 ± 9 vs. 45 ± 8 HU, p = 0.024). Significant differences were observed between the LPBV of the upper lung of the PH and control groups (34 ± 10 vs. 47 ± 10, p = 0.021 and 37 ± 10 vs. 47 ± 8, p < 0.001). A significant correlation was observed between the LPBV and the lung perfusion scintigraphy. A lower total LPBV and lower LPBV of the upper lung as detected by DECT might be specific findings of PH.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.