Abstract

Background: Levetiracetam is an antiepileptic drug used to prevent or treat seizure in patients with severe traumatic brain injury. This study aimed to develop and validate methodology suitable for measuring levetiracetam concentrations in human plasma and urine. Methods: Plasma or urine (10μl) samples were spiked with [2H6]-levetiracetam and processed using an acetonitrile precipitation. ESI-LC-MS/MS was employed for analyte detection. Results: The levetiracetam calibration was linear from 0.1 to 50mg/l in a combined matrix of plasma and urine. Intra- and inter-assay imprecision and accuracy in plasma were <7.7 and 109%, and in urine were <7.9 and 108%, respectively. Conclusion: The validated method was applied to a pharmacokinetic study of levetiracetam in critically ill patients with severe traumatic brain injury.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.