Abstract

Efforts on quantitative measurements of the interactive forces of red blood cells (RBC) have been pursued for many years in hopes of a better understanding of hemodynamics and blood rheology. In this paper, we report an approach based on an ultra-high frequency (410MHz) single beam acoustic tweezer (SBAT) for quantitative measurements of inter-RBC forces at a single cell level. The trapping forces produced by this ultra-high frequency (UHF) SBAT can be quantitatively estimated with a micropipette. Since the focal beam diameter of the 410MHz ultrasonic transducer used in this SBAT was only 6.5micrometer (μm), which was smaller than that of a RBC (~7.5μm), it was made possible to directly apply the beam to a single RBC and measure inter-RBC forces against the pre-calibrated acoustic trapping forces as another example of potential cellular applications of the SBAT. The magnitude of these forces was found to be 391.0±86.4pN. Finally, it is worth noting that unlike several other methods, this method does not require the measuring device to be in contact with the cells.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.