Abstract

Polyamide 11 films stabilized by Irganox® 1098, Irganox® 1010 or Irganox® 245 were subjected to thermal oxidation at 110 °C. The residual phenol content was assessed by comparing three analytical methods: high performance liquid chromatography (HPLC), determination of the Oxidation Induction Time (OIT) and Onset Oxidation Temperature (OOT) by thermal analyses. Both OIT and OOT are reliable for virgin PA11 after a relevant calibration by HPLC measurement. In the case of oxidized samples, OOT measurements have the benefits of being more easily interpretable than OIT and less time-consuming than HPLC measurements.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.