Abstract

We present a sensitive validated LC-MS/MS assay for the simultaneous determination of cabazitaxel and docetaxel in human plasma, with calibration ranges of 1.0-150 ng/mL for cabazitaxel and 0.1-15 ng/mL for docetaxel. Sample pretreatment consisted of liquid-liquid extraction with tert-butyl methyl ether. Chromatographic separation was achieved on a Zorbax Extend C18 column using a gradient mixture of 10mM ammonium hydroxide and methanol. Mass detection was carried out by turbo ion spray ionization in positive ion multiple reaction monitoring mode. All inter-day accuracies and precisions were within ±15% of the nominal value and within ±20% at the lower limit of quantitation. Demethylations of cabazitaxel yielding the metabolites RPR112698 and RPR123142 were monitored semi-quantitatively and quantified as ng docetaxel equivalents. Plasma samples of a prostate cancer patient treated with cabazitaxel were analyzed to demonstrate the usefulness of the presented assay for clinical drug monitoring. In conclusion, this method can be applied to support clinical pharmacokinetic studies with the novel anticancer drug cabazitaxel.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.