Abstract

The presence of antiphospholipid antibodies (aPLs) is associated with antiphospholipid syndrome (APS), characterized by thrombosis and obstetric morbidity. aPLs included in APS classification criteria are lupus anticoagulant, anti-cardiolipin and anti-beta-2-glycoprotein-I of IgG or IgM isotypes. Enzyme-linked immunosorbent assay is the most used diagnostic technique to determine aPLs. Recently, new automated technologies mainly based in antigen-coated beads have been developed. The aim is to compare a fluorescence enzyme immunoassay (M1) and an antigen-coated bead assay (M2) in obstetric and thrombotic APS patients. All samples from the first 1020 patients received in the Immune Service Laboratory (Hospital 12 de Octubre) during the recruitment period, without exclusions, were analysed for aPLs. The weighted kappa for both methods in all the patients was 0.39 (0.30-0.47). Agreement increased to 0.56 (0.38-0.73) in patients with autoimmune disease. Sensitivity and specificity obtained for M1 were 17.1% and 89.3%, respectively, and 12.7% and 91.4% for M2. The sensibility and specificity of IgG isotypes were higher than the IgM ones. Regarding obstetric patients, M1 obtained significant diagnostic performance and had more sensitivity 23.75 (14.95-34.58) compared to M2 12.50 (6.16-21.79). In conclusion, clinical suspicion-based method selection for aPLs should be considered. To identify obstetric APS patients, solid phase methods remain more preferable.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.