Abstract

IntroductionIn clinical trials of alemtuzumab, autoimmune thyroid adverse events (AEs) were frequent. Here, we assess the impact of thyroid AEs on health-related quality of life (HRQL) in alemtuzumab-treated patients with relapsing-remitting multiple sclerosis (RRMS).MethodsIn phase 3 CARE-MS I (NCT00530348) and II (NCT00548405) trials, patients with RRMS were administered alemtuzumab 12 mg/day on 5 consecutive days at baseline and on 3 consecutive days 12 months later. Patients could participate in an extension study (NCT00930553) through year 6. HRQL was assessed at baseline and annually using the Functional Assessment of Multiple Sclerosis (FAMS), EuroQoL-5 Dimension Visual Analog Scale (EQ-5D VAS), and 36-Item Short-Form Survey (SF-36) questionnaires. Outcomes were analyzed in patients with or without thyroid AEs (nonserious or serious). A subset of patients with thyroid AEs was analyzed to assess HRQL before and during the onset of thyroid AEs.ResultsA total of 811 CARE-MS patients were treated with alemtuzumab. Of these, 342 (42%) patients experienced thyroid AEs over 6 years; serious thyroid AEs occurred in 44 (5%) patients. At year 6, HRQL outcomes generally remained slightly improved or similar to core study baseline in alemtuzumab-treated patients with or without thyroid AEs: FAMS (least-squares mean change from baseline without thyroid AEs, 0.7; with nonserious thyroid AEs, 5.1; with serious thyroid AEs, − 5.3), EQ-5D VAS (2.0; 3.0; − 6.8), SF-36 mental component summary (MCS [0.6; 1.6; − 2.8]), SF-36 physical component summary (PCS [0.8; 1.0; 1.1]). Over 6 years, 63–82% of patients in each group had improved/stable SF-36 MCS and PCS scores. Among patients with thyroid AE onset in year 3 (peak incidence), there were minimal differences between HRQL outcomes before onset (year 2) and after onset (year 3).ConclusionAutoimmune thyroid AEs (serious and nonserious) had minimal impact on HRQL in alemtuzumab-treated patients. These data may aid therapeutic decisions in patients with relapsing MS.Electronic supplementary materialThe online version of this article (10.1007/s40120-020-00191-7) contains supplementary material, which is available to authorized users.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.