Abstract

Paroxysmal atrial fibrillation (PAF) is a frequent cause of recurrent stroke but can be difficult to detect because of its episodic and often asymptomatic nature. We sought to improve rate of PAF detection through a quality improvement project (QIP) to deliver early prolonged inpatient cardiac monitoring on the stroke unit (SU). A structured protocol for cardiac monitoring using 5-day event recorders was established. 'In-house' cardiac monitoring was implemented. Performance data on this change in service was analysed prospectively and summary statistics obtained. One-hundred and two ischaemic stroke (IS) patients undertook 5-day event recorder monitoring. Provision of monitors as an inpatient (IP) increased from 20% (pre-QIP pilot 2018) to 65.7% (during QIP). New AF was detected in 15 patients (14.7% vs 8.6% pre-QIP pilot 2018) with majority of new AF (13 patients; 19%) detected when monitors applied early (IP) after IS. Although this study had a number of limitations, it did demonstrate that early and prolonged non-invasive IP cardiac monitoring could be delivered 'in-house' on the SU and improve AF detection rates.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.