Abstract

An ultrasensitive absorptiometric procedure for the determination of clenbuterol in pharmaceutical preparations was developed. Clenbuterol was diazotized with nitrite and coupled with 1-(naphthyl)ethylenediamine, and the absorbance of the azo dye formed was measured by both spectrophotometry and ultrasensitive thermal lens spectrometry (TLS). The TLS limit of detection was 1.5 ppb, 14-fold lower than with a Hewlett-Packard diode array spectrophotometer. Thus, the TLS procedure can be advantageously applied to quality control of clenbuterol at the individual dose level and in small samples. Repeatability as relative standard deviation was 1.5% (50 ppb, n = 6).

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.