Abstract

The present study's objective was to control the quality of different mitigation methods for unusually high indoor radon (222Rn) concentrations of up to 274,000 Bq m(-3) in a village (Umhausen, 2,600 inhabitants) in western Tyrol, Austria. Five years after mitigation, five different remedial actions were examined on their quality by means of measuring indoor radon concentrations with charcoal liquid scintillation radon detectors and with a continuously recording AlphaGuard detector. Mitigation method in house 1--a mechanical intake and outlet ventilation system with heat exchanger in the basement, combined with a soil depressurization system--was characterized by long-term stability. With most favorable air pressure (+100 Pa) in the basement, mean basement radon concentrations in the winter were reduced from 200,000 Bq m(-3) to 3,000 Bq m(-3) by this method 5 y after mitigation. Acting against experts' instructions, the inhabitants had switched off the ventilation system most of the time to minimize power consumption although it had been proven that ventilation reduced mean basement radon concentration by a factor of about 3 in the winter and about 15 in the summer. Mitigation method in house 2-soil depressurization with two fans and loops of drainage tubes to withdraw radon from the region below the floor and outside the basement walls, and from soil below that part of the house with no basement-had been the most successful remedial measure until the winter of 1999 (i.e., 6 y after mitigation), when micro-cracks opened and consequently mean basement radon concentration increased from 250 Bq m(-3) to 1,500 Bq m(-3). Measures to block these microcracks and to minimize soil drying are being developed. Five years after mitigation, the remedial method used in house 3--a multilayer floor construction, where a fan was used to suck radon from a layer between bottom slab and floor-reduced winter mean radon concentration from 25,000 Bq m(-3) to 1,200 Bq m(-3), with the ventilation on and the basement door open. Mitigation method in house 4--a basement sealing technique--was unsuccessful with almost identical radon concentrations during all the five years since mitigation had started. Mitigation method in house 5--a waterproof basement technique especially for future homes--reduced mean basement radon concentration below 300 Bq m(-3) and mean ground floor radon concentration below 200 Bq m(-3), which is the Austrian action level for newly constructed buildings. These findings indicate that even in areas with extremely high radon concentrations, effective mitigation of indoor radon can be achieved provided that house-specific long-term, stable mitigation techniques are applied.

Full Text
Published version (Free)

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call