Abstract

AbstractThe aim of this study was to develop and validate a robust reversed‐phase high‐performance liquid chromatography (RP‐HPLC) method for the simultaneous estimation of neomycin sulfate (NEO) and beclomethasone dipropionate (BECLO) in both bulk drug and pharmaceutical dosage forms. The analysis was conducted using the Box‐Behnken design. The separation of NEO and BECLO was conducted on a Phenomenex Luna C‐18 column (4.6 × 150 mm, 5 µm), employing a mobile phase comprising a mixture of methanol and trifluoroacetic acid in a ratio of 88:12% v/v. The separation was performed at a flow rate of 0.6 mL/min. NEO and BECLO were analyzed at a wavelength of 240 nm employing a photodiode array detector. The validation of the methodology followed the guidelines outlined in the International Council for Harmonization Q2 R (1). The validation process involved assessing critical parameters such as linearity, accuracy, system suitability, precision, and robustness. The results for each parameter were found to be within the acceptable range. The results indicate that the established RP‐HPLC method can effectively be employed for the routine analysis of NEO and BECLO in bulk drug and pharmaceutical dosage forms.