Abstract
Two methods are proposed for obtaining extrinsic oxide lifetime data using fast ramped tests. It is shown that the intersection point between the extrinsic and intrinsic branches of a Weibull plot coincides for ramped and constant stress tests. This is the basis of our fast qualification approach, where intrinsic data are obtained by constant voltage stress and extrinsic data are cumulated with a fast ramped test. The correctness of our approaches is supported by constant voltage and exponentially ramped current measurements.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.