Abstract
To achieve the first plasma of the Korea superconducting tokamak advanced research (KSTAR), the KSTAR superconducting coils were tested in advance. As they should operate in excessively low temperature of 4.5 K and high magnetic field environment of 7.5 T, it is crucial to monitor the cryogenic and the structural behaviors of KSTAR device during the commissioning period including a cool-down. The temperatures of the KSTAR toroidal field (TF) coil and the poloidal field (PF) coils were measured during the entire operating period. The mechanical stresses on the TF and PF structures were continuously monitored to check if they go beyond the limiting value calculated through the simulation. The alignment of the KSTAR device was checked by using displacement sensors. The TF coils were successfully supplied with 15 kA DC current for 8 hours, and the maximum 5 kA/s current variation of the PF coils were tested. For the main experiment, the interlock test of the quench detection system for the KSTAR coils was carried out at reduced currents of 1 kA. From these results the quench protection circuit, and the current-flow of the KSTAR superconducting coils proved to be well performed for the first plasma operation.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.