Abstract
A method for calibration and measurement with a fourwire probe is described. The method does not require any assumption about the response of the wires and it is not necessary to know the exact probe geometry. Measurements in a two-dimensional turbulent boundary layer showed large errors in the \(\overline {\upsilon \prime w\prime } \) shear stress, although the probe had a wire arrangement practically insensitive to mean velocity gradients normal to the wall. The problem seems to be caused by the strong instantaneous spanwise velocity gradients, as suggested by the computed response of a simple probe model inserted into a numerical flow obtained by direct simulation.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.