Abstract

BackgroundAmiodarone causes less drug-induced torsade de pointes (TdP) compared to other class III antiarrhythmics. Two theories proposed for this finding include that amiodarone has less repolarization heterogeneity, and/or decreases early after depolarization (EADs). Corrected QT (QTc) dispersion as measured on a surface electrocardiogram (ECG) represents spatial heterogeneity of ventricular repolarization.ObjectiveThe purpose of this study was to analyze the difference in QT dispersion between amiodarone and other class III antiarrhythmics and to determine the etiology of TdP.MethodsThis was a retrospective, observational study at Montefiore Medical Center between January 2005 and January 2015. Inclusion criteria were adults >18 years on amiodarone, dofetilide, or sotalol with prolonged QT interval on 12-lead ECG. ECGs were reviewed by three blinded observers. QTc was calculated using the Bazett and Framingham formulas. QTc dispersion was calculated by subtracting the shortest from the longest QTc. Analysis of variance (ANOVA) was applied for comparison between antiarrhythmic groups with Bonferroni correction for multiple comparisons.ResultsA total of 447 ECGs were reviewed and 77 ECGs met inclusion criteria. The average QT dispersion for amiodarone, dofetilide, and sotalol was 0.050, 0.037, and 0.034, respectively (p=0.006) and the average QTc dispersion by Bazett was 0.053, 0.038, and 0.037 (p=0.008) and by Framingham was 0.049, 0.036, and 0.035 (p=0.009), respectively.ConclusionOur results show that given the increase in QT dispersion seen with amiodarone, heterogeneous ventricular repolarization as measured by QTc dispersion likely does not account for the lower incidence of drug-induced TdP seen with amiodarone. The ability of amiodarone to decrease EADs via sodium-channel blockade is more likely the explanation for its lower incidence of drug-induced TdP.

Highlights

  • QT dispersion, defined as the difference between the largest and smallest QT intervals in all the leads of a surface electrocardiogram (ECG), has been studied extensively over the past 30 years [1]

  • Our results show that given the increase in QT dispersion seen with amiodarone, heterogeneous ventricular repolarization as measured by QTc dispersion likely does not account for the lower incidence of drug-induced torsade de pointes (TdP) seen with amiodarone

  • Analysis and comparison of the effect of different class III antiarrhythmic agents on QT dispersion can help further understand the mechanism of this paradoxical effect of amiodarone: whether the low incidence of TdP by amiodarone despite its QT-prolonging effect is mediated by increasing homogeneous ventricular repolarization or by its effects on reducing early after-depolarizations (EADs) [14,15,16]

Read more

Summary

Background

Amiodarone causes less drug-induced torsade de pointes (TdP) compared to other class III antiarrhythmics. Two theories proposed for this finding include that amiodarone has less repolarization heterogeneity, and/or decreases early after depolarization (EADs). Corrected QT (QTc) dispersion as measured on a surface electrocardiogram (ECG) represents spatial heterogeneity of ventricular repolarization

Methods
Results
Conclusion
Introduction
Materials And Methods
Discussion
Conclusions
Disclosures
Hohnloser SH
25. Shah RR
Full Text
Published version (Free)

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call