Abstract

Biomedical wireless sensor networks are a key technology to support the development of new applications and services targeting patient monitoring, in particular, regarding data collection for medical diagnosis and continuous health assessment. However, due to the critical nature of medical applications, such networks have to satisfy demanding quality of service requirements, while guaranteeing high levels of confidence and reliability. Such goals are influenced by several factors, where the network topology, the limited throughput, and the characteristics and dynamics of the surrounding environment are of major importance. Harsh environments, as hospital facilities, can compromise the radio frequency communications and, consequently, the network’s ability to provide the quality of service required by medical applications. Furthermore, the impact of such environments on the network’s performance is hard to manage due to its random and unpredictable nature. Consequently, network planning and management, in general or step-down hospital units, is a very hard task. In such context, this work presents a quality of service based management tool to help healthcare professionals supervising the network’s performance and to assist them managing the admission of new sensor nodes (i.e., patients to be monitored) to the biomedical wireless sensor network. The proposed solution proves to be a valuable tool both, to detect and classify potential harmful variations in the quality of service provided by the network, avoiding its degradation to levels where the biomedical signs would be useless; and to manage the admission of new patients to the network.

Highlights

  • Patients’ monitoring in general or step-down hospital units is crucial to avoid clinical worsening of inpatients (Alemdar and Ersoy 2010; Nouira and Trabelsi 2012)

  • This paper proposes a new Quality of Service (QoS)-based network management system for Biomedical Wireless Sensor Networks (BWSNs) comprised by two modules, namely the QoS monitoring module and the admission control module

  • The admission control module is used to verify if a new sensor node can be admitted by the BWSN in the requested area

Read more

Summary

Introduction

Patients’ monitoring in general or step-down hospital units is crucial to avoid clinical worsening of inpatients (Alemdar and Ersoy 2010; Nouira and Trabelsi 2012). In most cases, despite the necessity of continuous monitoring, nursing professionals measure vital or physiological signs (e.g., temperature, pulse and respiratory rates, blood pressure or oximetry) manually a few times a day. Such episodic measurements can be complemented by efficient and reliable real-time monitoring systems, bringing out an enhancement of the quality of care, while freeing the nursing staff to provide extra attention to the inpatients (Chipara et al 2010; Ko et al 2010b). Due to its flexibility and low energy consumption, BWSNs have been successfully used in several patient monitoring scenarios (Alemdar and Ersoy 2010; Honeine et al 2011)

Methods
Results
Conclusion
Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call