Abstract

The application of a Pt/PZT/Pt sandwich structure in place of a polysilicon material for a xylophone magnetometer bar can greatly improve the sensitivity of the device. This is the first time a piezoelectric activation has been used to resonate a xylophone bar comprised of SiO2/Ta/Pt/PZT/Pt. Both optical beam and scanning laser Doppler vibrometer methods were used for characterizing the bar deflection. A fabrication process for freely suspended xylophone magnetometer bars is presented. When the device was placed in a vacuum ambient the Quality factor improved to a value of 1800.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.